Epoxies - 2 Component

INSULCAST 125
LOW VISCOSITY EPOXY POTTING/CASTING COMPOUND

DESCRIPTION

INSULCAST 125 is a low viscosity, general purpose potting and casting compound. The low viscosity enables it to be used in potting densely packed modules, thereby insuring good flow and penetration around components. INSULCAST 125 contains non-abrasive fillers.

PROPERTIES-UNCURED:
  Insulcast
125
Insulcure
9
Insulcure
11B
 
PROPERTIES UNCURED:
Color, visual Black Amber Amber  
Viscosity @25°C, cps 7,500 55 700  
Specific Gravity 1.55 0.97 0.95 ASTM D 1475
Mix Ratio (by weight) 100 :6-7 :9-10  
Mixed viscosity @25°C, cps   3,000 2,500  
Pot Life (100 grams)@25°C, hrs   1 2.5  
Shelf Life @72°F, months 12 12 12  
PROPERTIES-CURED:
PHYSICAL:
Hardness, Durometer (Shore D)   80 85 ASTM D 2240
Tensile Strength, psi   11,000 11,500 ASTM D 638
Tensile Elongation, %   2.5 2.0 ASTM D 638
Flexural Strength, psi   14,500 15,000 ASTM D 790
Compressive Strength, psi   12,500 13,000 ASTM D 695
Coefficient of Thermal Expansion, °C   48 x 10-6 48 x 10-6  
Thermal Conductivity, BTU-in/(ft2)(hr)(°F)   4.5 4.3  
Heat Distortion Point, °C   80 155  
Service Temperature, °C   105 155  
ELECTRICAL:
Dielectric Strength, volts/mil   415 420 ASTM D 147
Dielectric Constant, 1 KHz   4.2 4.2 ASTM D 150
Dissipation Factor, 1 KHz   0.023 0.02 ASTM D 150
Volume Resistivity   5 x 1014 9 x 1014 ASTM D 257

USE INSTRUCTIONS:

1. Stir INSULCAST 125 thoroughly in its original container until uniform and any settled filler is completely reincorporated.
2. Weigh out required amount of INSULCAST 125 and weigh in 6-7 parts INSULCURE 9 per 100 parts of INSULCAST 125, or 9-10 parts INSULCURE 11B per 100 parts INSULCAST 125.
3. Mix thoroughly.
4. De-air (if necessary) at 29 in Hg. for 10 minutes.
5. Pour into mold, module or cavity.

CURE SCHEDULES:
INSULCURE 9: 16 TO 24 HOURS @250C.
INSULCURE 11B: 2 hours at 80°C plus 1 hr. at 150°C

IMPORTANT:
The following supersedes any provision in your company's forms, letters and papers. AMERICAN SAFETY TECHNOLOGIES, INC. makes NO WARRANTY, WHETHER EXPRESSED OR IMPLIED, INCLUDING WARRANTIES of MERCHANTABILITY OR of FITNESS FOR A PARTICULAR PURPOSE FOR THIS PRODUCT. No statements or recommendations contained in the product literature are to be construed as inducements to infringe any relevant patent, now or thereafter in existence. UNDER NO CIRCUMSTANCES SHALL AMERICAN SAFETY TECHNOLOGIES, INC. BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES FROM ALLEGED NEGLIGENCE, BREACH of WARRANTY, STRICT LIABILITY OR ANY OTHER THEORY, ARISING OUT of THE USE OR HANDLING of THIS PRODUCT. The sole liability of AMERICAN SAFETY TECHNOLOGIES, INC. for any claims arising out of the manufacture, use or sale of its products shall be to refund the buyer's purchase price, provided such products have been demonstrated in AMERICAN SAFETY TECHNOLOGIES, INC. sole opinion, to justify such refund.

HEALTH CAUTION:
Avoid breathing possible fumes, mists and vapors which can cause severe respiratory damage. Use of NIOSH approved breathing apparatus is required for more than minimal exposure. Always work in areas with adequate ventilation to allow dissipation of polyamine and other chemical fumes, and where applicable, solvent fumes. Use of goggles, protective garments, rubber gloves, protective cream is required. If material gets into eyes, flush thoroughly with clear water for twenty (20) minutes; then seek medical treatment. Avoid skin contact. Material can cause contact dermatitis. Always wash exposed areas immediately, using warm water and soap, followed by rinsing with clean water. Observe all safety precautions. It is important when using solvent based materials or solvents to keep away from open flame or ignition source.

PLEASE REFER TO MATERIAL SAFETY DATA SHEET FOR FURTHER FIRST AID INFORMATION.

FOR CHEMICAL EMERGENCY
CALL CHEMTREC (DAY OR NIGHT) 800 424-9300.