DESCRIPTION

RTVS 570 is a low viscosity, primerless silicone encapsulant with good reversion resistance. The equal mix ratio makes RTVS 570 ideal for automatic dispensers. With the ability to develop good adhesion to most substrates without the use of a primer. RTVS 570 combines the virtues of low temperature flexibility, excellent electrical properties, high temperature resistance and repairability.

PROPERTIES-UNCURED:
  Part A Part B  
Color, visual Black Off White  
Viscosity, cps 4,000 1,500 ASTM D 1084
Specific Gravity 1.38 1.38  
Mix Ratio (by weight) 1:1  
Mixed Viscosity, cps 3,000  
Working Time @72°F, hours 24  
Shelf Life @72°F, months 6  
PROPERTIES-CURED:
PHYSICAL:
Hardness, Durometer (Shore A) 38 ASTM D 2240
Tensile Strength, psi 200 ASTM D 412
Tensile Elongation, % 100 ASTM D 412
Lap Shear, ppi (unprimed AL to AL) 200 ASTM D 624
Coefficient of Thermal Expansion, °C 26 x 10-5  
Thermal Conductivity, BTU-ft/(ft2)(hr)(°F) 0.21  
Thermal Conductivity, BTU-in/(ft2)(hr)(°F) 2.52  
Service Temperature, °C -55 to 204  
ELECTRICAL:
Dielectric Strength, volts/mil 450 ASTM D 149
Dielectric Constant, 1 KHz 3.15 ASTM D 150
Dissipation Factor, 1 KHz 0.008 ASTM D 150
Volume Resistivity, ohm-cm 1 x 1015 ASTM D 257

MIXING INSTRUCTIONS:

1. Premix RTVS 570 Part A and Part B in original containers before withdrawing any material. Some light, but soft, settling will occur which readily re-disperses.
2. Measure equal proportions either weight or volume of Part A and Part B.
3. Mix thoroughly, scraping the sides and bottom of the mixing container.
4. Evacuate the mixture at 29 in. Hg for 3-4 minutes for void-free castings.
5. Pour into unit or mold.

CURE SCHEDULE:
2 hours at 150°C.
*Post Cure at 100°C for 1 hour will give good adhesion.

SPECIAL NOTES:
Certain materials may inhibit the cure of RTVS 570 when placed in contact with the mixed, uncured rubber. Materials such as amines and amine cured epoxies, sulfur containing materials and condensation (tin cured) silicones, are some which may cause inhibition. Even surfaces which have been in contact with such materials may cause it. If in doubt, a patch test should be done.

IMPORTANT:
The following supersedes any provision in your company's forms, letters and papers. AMERICAN SAFETY TECHNOLOGIES, INC. makes NO WARRANTY, WHETHER EXPRESSED OR IMPLIED, INCLUDING WARRANTIES of MERCHANTABILITY OR of FITNESS FOR A PARTICULAR PURPOSE FOR THIS PRODUCT. No statements or recommendations contained in the product literature are to be construed as inducements to infringe any relevant patent, now or thereafter in existence. UNDER NO CIRCUMSTANCES SHALL AMERICAN SAFETY TECHNOLOGIES, INC. BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES FROM ALLEGED NEGLIGENCE, BREACH of WARRANTY, STRICT LIABILITY OR ANY OTHER THEORY, ARISING OUT of THE USE OR HANDLING of THIS PRODUCT. The sole liability of AMERICAN SAFETY TECHNOLOGIES, INC. for any claims arising out of the manufacture, use or sale of its products shall be to refund the buyer's purchase price, provided such products have been demonstrated in AMERICAN SAFETY TECHNOLOGIES, INC. sole opinion, to justify such refund.

HEALTH CAUTION:
RTV silicone rubber base compounds and the curing agents for addition cure products are non-hazardous and practically non-toxic. Curing agents for condensation cure products contain tin soaps which can irritate eyes and skin of some individuals. Avoid contact with skin; if contact occurs, wash affected areas at once with soap and water. Avoid contact with eyes. In case of contact with eyes, flush with water for 15 minutes; call a physician.

PLEASE REFER TO MATERIAL SAFETY DATA SHEET FOR FURTHER FIRST AID INFORMATION.

FOR CHEMICAL EMERGENCY
CALL CHEMTREC (DAY OR NIGHT) 800 424-9300.

For Technical Bulletins Click Here...

©2007 ITW Insulcast - ITW Polymer Technologies. All rights reserved.