INSULCAST 141 VERY HIGH THERMAL CONDUCTIVITY CASTING COMPOUND
DESCRIPTION
INSULCAST 141 is a high viscosity, highly filled epoxy formulation which in addition to having excellent electrical properties, has high thermal conductivity and low thermal expansion.
| PROPERTIES-UNCURED: |
| | Insulcast 141 | Insulcure 9 | Insulcure 11B | |
| PROPERTIES UNCURED: |
| Color, visual | Black | Amber | Amber | |
| Viscosity @25°C, cps | 200,000 | 55 | 700 | ASTM D 2393 |
| Specific Gravity | 2.3 | 0.97 | 0.95 | |
| Mix Ratio (by weight) | 100 | :3-4 | :4-5 | |
| Mixed Viscosity, cps | | 100,000 | 95,000 | |
| Pot Life (100 grams @25°C, hrs.) | |
1 | 2-3 | |
| Shelf Life @72°F, months | 12 | 12 | 12 | |
| PROPERTIES-CURED: |
| PHYSICAL: |
| Hardness, Durometer (Shore D) | | 92 | 92 | ASTM D 2240 |
| Tensile Strength, psi | | 8,000 | 8,500 | ASTM D 638 |
| Tensile Elongation, % | | 1.0 | 1.0 | ASTM D 638 |
| Compressive Strength, psi | | 15,000 | 16,500 | ASTM D 695 |
| Flexural Strength, psi | | 11,500 | 13,000 | ASTM D 790 |
| Coefficient of Thermal Expansion, °C | | 28 x 10-6 | 28 x 10-6 | |
| Thermal Conductivity, BTU-in/(ft2)(hr)(°F) | | 10 | 10 | |
| Heat Distortion Point, °C | | 80 | 155 | |
| Service Temperature, °C | | 105 | 155 | |
| ELECTRICAL: |
| Dielectric Strength, volts/mil | | 475 | 550 | ASTM D 149 |
| Dielectric Constant, 1 KHz | | 6.3 | 6.5 | ASTM D 150 |
| Dissipation Factor 1 KHz | | 0.02 | 0.02 | ASTM D 150 |
| Volume Resistivity | | 4.0 x 1016 | 5.0 x 1016 | ASTM D 257 |
MIXING INSTRUCTIONS:
- Warm INSULCAST 141 to 40°-55°C and stir contents thoroughly, before to room
withdrawing any material. If INSULCURE 9 is used, allow INSULCAST 141 to return temperature (25°C) prior to adding curing agent.
- Weigh out the required amount of INSULCAST 141. Weigh out required amount of curing agent (see mix ratio).
- Mix thoroughly, being certain to scrape sides and bottom of container.
- De-air at 29 in. Hg for 10-15 minutes.
- Pour into mold or cavity.
CURE SCHEDULE:
INSULCURE 9: 24 hours at room temperature (25°C), or 2 hours at 65°C.
INSULCURE 11B: 2 hours at 100°C, plus 2 hours at 125°C.
For service temperature above 150°C, post cure 2-3 hours at 150°C.
IMPORTANT:
The following supersedes any provision in your company's forms, letters and papers. AMERICAN SAFETY TECHNOLOGIES, INC. makes NO WARRANTY, WHETHER EXPRESSED OR IMPLIED, INCLUDING WARRANTIES of MERCHANTABILITY OR of FITNESS FOR A PARTICULAR PURPOSE FOR THIS PRODUCT. No statements or recommendations contained in the product literature are to be construed as inducements to infringe any relevant patent, now or thereafter in existence. UNDER NO CIRCUMSTANCES SHALL AMERICAN SAFETY TECHNOLOGIES, INC. BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES FROM ALLEGED NEGLIGENCE, BREACH of WARRANTY, STRICT LIABILITY OR ANY OTHER THEORY, ARISING OUT of THE USE OR HANDLING of THIS PRODUCT. The sole liability of AMERICAN SAFETY TECHNOLOGIES, INC. for any claims arising out of the manufacture, use or sale of its products shall be to refund the buyer's purchase price, provided such products have been demonstrated in AMERICAN SAFETY TECHNOLOGIES, INC. sole opinion, to justify such refund.
HEALTH CAUTION:
Avoid breathing possible fumes, mists and vapors which can cause severe respiratory damage. Use of NIOSH approved breathing apparatus is required for more than minimal exposure. Always work in areas with adequate ventilation to allow dissipation of polyamine and other chemical fumes, and where applicable, solvent fumes. Use of goggles, protective garments, rubber gloves, protective cream is required. If material gets into eyes, flush thoroughly with clear water for twenty (20) minutes; then seek medical treatment. Avoid skin contact. Material can cause contact dermatitis. Always wash exposed areas immediately, using warm water and soap, followed by rinsing with clean water. Observe all safety precautions. It is important when using solvent based materials or solvents to keep away from open flame or ignition source.
PLEASE REFER TO MATERIAL SAFETY DATA SHEET FOR FURTHER FIRST AID INFORMATION.
FOR CHEMICAL EMERGENCY CALL CHEMTREC (DAY OR NIGHT) 800 424-9300.
11/98
|